Basic Info.

Model NO.
LDR
Steam Volume
20 T/H
High Volt Input
10 Kv/50Hz
AMP
867 a
Steam Pressure
1.0 MPa
Temperature of Steam
184 C
Thermal Supply Backflow
20 C
Transport Package
Wooden Case
Specification
15MW
Trademark
Liyuan
Origin
China

Product Description

Electrode Phase Transition Boiler Steam Boiler 10KV 15MW

Operation principle
The electrode phase transition boiler (steam), is a type of electrode boiler which will produce steam through the phase transition inside boiler. The 3PH electrodes are installed in the electrode tube, which is immersed into media water with minimal conductivity. When the electricity is power on, the media water will be quickly heated into media steam with the of electric current. The media steam flows along the first side of heat exchanger (external of heat exchange tube), transfer thermal to the second side of heat exchanger (internal
cold water in heat exchanger tube), turn cold thermal supply water into steam supply. The media steam will be condensed and flow back to media tank to be gasified again, one complete cycle is finished.
Electrode Phase Transition Boiler Steam Boiler 10kv 15MW
Key features
1. Non-spay type
Fully immersed, not inner-outer bushing style. Patent, safer and more stable.
2. Phase transition heat exchange
Structure: boiler with built-in heat exchanger, protected from influence of thermal supply water quality, stable run.
3. Fixed electrode modular
Innovative electrode design, be made of composite materials, and precisely laser positioned. No moving parts, only a small canned pump for adjusting media water level, super reliable.
4. Constant conductivity
Media water phase transition in closed chamber, ensures constant conductivity, no drainage at first side, hence no need conductivity adjusting.
System diagram - electrode phase transition steam boiler
Electrode Phase Transition Boiler Steam Boiler 10kv 15MWSystem diagram ( electrode phase transition steam boiler + high pressure steam thermal store
(direct boiler steam thermal supply,steam thermal store,steam thermal supply,simultaneously store and supply of thermal steam, etc)
Electrode Phase Transition Boiler Steam Boiler 10kv 15MW
Technical data
Model LDR- 2 4 6 8 10 15 20
Steam volume t/h 2 4 6 8 10 15 20
Power kW 1.5 3.0 4.5 6.0 7.5 11.3 15.0
Amp A 87 174 260 347 434 650 867
High volt power source kV/Hz 10 kV / 50 Hz
Cable specification mm2 35 50 95 150 240 150 240
Numbers of electrode/cable pieces/piece 3 6
Control cabinet volt V/HZ 380V/50HZ
Control cabinet power kw 18.0 19.8 21.3 26.8 26.8 30.8 34.3
Steam pressure Mpa 1.0
Steam temperature ºC 184
Thermal supply backflow temperature ºC 20
Diameter of water inlet DN(mm) 50 80
Diameter of main valve (steam) DN(mm) 65 100 125 150 150 200 200
Dia. of safety valve at first side DN(mm) 2-32 2-50 2-65 2-80 2-80 2-100 2-100
Dia of safety valve at second side DN(mm) 50 80 100 100 125 2-125 2-125
Dia of drain valve at first side DN(mm) 2-40
Dia of drain valve at second side DN(mm) 40 50
Overall dimension L (mm) 4550 4550 4950 5350 5350 6150 6150
W (mm) 2210 2210 2510 2710 2710 3110 3110
H (mm) 3250 3250 3350 3450 3450 3650 3650
Shipping weight Ton 4.3 4.3 5.2 6.0 6.0 8.7 8.7
Operation weight Ton 8.6 8.6 11.0 13.5 13.5 20.5 20.5
Dimension of heat exchanger L (mm) 1200 1400 1600 1800 1800 1800 1800
W (mm) 1200 1400 1600 1800 1800 1800 1800
H (mm) 3800 4100 4200 4300 4300 4300 4300
Shipping weight Ton 2.0 2.0 3.4 4.6 4.6 2x4.6 2x4.6
Operation weight Ton 2.4 2.7 4.5 6.4 6.4 2x6.4 2x6.4
Notes:1,High voltage: 10kV/50Hz/3PH. Cable specification: ZR-YJV-8.7/15-1*X (single core: X sectional area), should be ready to be connected to boiler's electrode and prepared by client. The boiler body should be reliably earthed (Resistance≤4Ω). 3 Phase power source and the
analog signal of zero-sequence current be available to main control cabinet of boiler. The main control cabinet can turn on/off the vacuum circuit break in the high volt power source by switching signal;
2,Power of control cabinet: 380V/50Hz (3Phase-5wires);
3,the main power cable should be ready and prepared by client;
4,The electrode boiler is a pure resistive load, no need capacity cabinet for high volt power
5,Standard steam pressure: 1.0 Mpa (Please contact us if >1.0Mpa will be needed)
6,Adjustable thermal supply range: 5%-100%;
7,Raw water supply requirements: hardness≤0.03mmol/L;
8,Overall dimension excluded of handrail, valves, pipelines, weight excluded of heat exchanger frame, joint pipelines, steam distributor;
9,Definition of model:
Electrode Phase Transition Boiler Steam Boiler 10kv 15MW
Projects
Electrode Phase Transition Boiler Steam Boiler 10kv 15MWElectrode Phase Transition Boiler Steam Boiler 10kv 15MW

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now