Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MW

After-sales Service: Maintenance Free
Warranty: 10 Years
Type: Stainless Steel Heating Equipment
Certification: ISO, ASME
Structure: Vertical Type
Brand: Runpaq
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Zhejiang, China
Fast Delivery
The supplier can deliver the goods within 30 days
Customization from Samples
The supplier provides sample based customization services
Customization from Designs
The supplier provides design based customization services
ODM Services
The supplier provides ODM services
to see all verified strength labels (7)

Basic Info.

Model NO.
LDR
Thermal Capacity
40 MW
Input Power
40 MW
High Volt Input
10 Kv/50Hz
AMP
2309 a
Cable Spec
240 mm2
Nos of Electrode
18
Thermal Supply Flow
572 M3/H
Pressure Loss
80 Kpa
Transport Package
Wooden Case
Specification
40MW
Trademark
Liyuan
Origin
China

Product Description

Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kV 40MW

The electrode pressure phase transition boiler, can produce hot water or steam. Its energy transition efficiency is nearly 100%, max thermal capacity is up to 40 MW

Operation principle
The electrode phase transition boiler (hot water), is a type of electrode boiler. The phase transition happens
inside the boiler to realize heat exchange. It consists of: electrode tube, media tank, heat exchanger, and
control cabinet. The 3PH electrodes are fixed in the electrode tubes, which are immersed into media water
with minimal conductivity. When the electricity is power on, the media water will be directly heated. The
current is transformed into thermal, so media water is quickly gasified and function as media steam, which will
rise to heat exchanger, so the thermal is transferred to the thermal supply water inside the heat exchanger
tube. Simultaneously, the media steam will be condensed then drop back to media water tank. One complete
process has been finished. The media water will repeat this phase transition process:
gasification-condensation-gasification during the boiler running time, to realize the transition from electricity
into thermal. The thermal supply power is decided by the immerse depth of electrode into the media water,
whose adjustable range: 1%-100%.
Temperature of thermal supply water(≤110ºC): electrode micro-pressure/phase transition boiler(free
from supervision and inspection); Temperature of thermal supply water(>110ºC): electrode pressure
transition boiler.
Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MW
Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MW
Key features
1. Constant conductivity simplified
The media water is filled in one time, circulating in the closed chamber, no contact with external. Consequently, there is no electrochemical corrosion, hence constant conductivity can be ensured; No needs of conductivity adjusting system, on-time monitor. More easily operation.
2. Fixed electrode modular safe and reliable
Innovative electrode design, be made of composite materials, precisely laser positioned. No moving parts, only a small canned pump for adjusting media water level, super reliable.
3. Phase transition heat exchange simplified
Built-in heat exchanger, directly connected to the thermal supply system, no need external heat exchanger. Save the cost of one-time circulation pump, plate heat exchanger, greatly simplify the system, minimize initial investment and floor area, much higher efficient.
4. Thermal store system freely switch
The two built-in heat exchangers for the thermal supply or thermal store, can freely switch among: supply thermal, store thermal, or simultaneously supply and store thermal even without electric valve.
Technical data
Model LDR- 1.4 2.8 4.2 5.6 7 8 10 12 14 16 18 20 24 29 40
Rated thermal supply MW 1.4 2.8 4.2 5.6 7 8 10 12 14 16 18 20 24 29 40
High volt power source kV/Hz 10 kV / 50Hz
Input power MW 1.4 2.8 4.2 5.6 7 8 10 12 14 16 18 20 24 29 40
Input current Amp 81 162 242 323 404 462 577 693 808 924 1039 1155 11386 1674 2309
Cable specification &
Nos of electrodes/cables
mm2 50 70 120 185 240 240 150 185 240 240 185 240 300 300 240
pc/pc 3 6 9 18
Control cabinet power V/Hz 380V/50HZ/25KW  
Temp.of supply/backflow ºC 130/70ºC  
Thermal supply water flow m3/h 20 40 60 80 100 115 143 172 200 229 300 416 572 416 572
Pressure drop kPa 30 35 40 40 80 80 80 80 80 80 80 80 80 80 80
Connect port DN(mm) 80 200 250 250 350 350 400 450 500 500 500 500 600 500 600
Overall dimension L (mm) 4060 4760 4960 5460 5660 5660 7660 7660 8760 8760 8760 8760 8760 8760 8760
W (mm) 2060 2260 2460 2560 2760 2760 2760 3560 4060 4060 3770 3770 3770 3770 7540
H (mm) 3060 3250 3510 3660 3810 3810 3810 3860 3860 3860 6400 6400 6400 6400 6400
Shipping weight Ton 4.0 5.2 5.5 6.9 7.8 7.9 8.3 10.5 16.5 17.2 23.5 28.6 31.4 33.5 67.8
Operation weight Ton 6.5 8.8 9.3 11.8 13.0 13.2 13.8 21.5 31.5 32.2 45.5 50.5 52.5 56.5 128.5
Note:
1,High voltage: 10kV/50Hz/3PH. Cable specification: ZR-YJV-8.7/15-1*X(single core: X sectional area), should be ready to be connected to boiler's electrode and prepared by client. The boiler body should be reliably earthed (Resistance≤4Ω); 3 Phase power source and the analog signal
of zero-sequence current be available to main control cabinet of boiler. The main control cabinet can turn on/off the vacuum circuit break in the high volt power source by switching signal;
2,Power of control cabinet: 380V/50Hz (3Phase-5wires);
3,the main power cable should be ready and prepared by client;
4,The electrode boiler is a pure resistive load, no need capacity cabinet for high volt power;
5,Max thermal supply temp: 150ºC;
6,Adjustable thermal supply range: 5%-100%;
7,Overall dimension for reference only,varies depending on actual project;
8,Definition of model:
Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MW
SBS Smart Boiler system:
SBS(Smart Boiler System)integrated boiler system (thermal supply) is a thermal supply system, which is consisted of: electric/electrode boiler, circulation pump system, water softener, supply pump system (for constant pressure), control system, lighting system, alarming system, all systems are prefabricated into a container before delivery. The SBS is protected from wind, rain and cold. It can be outdoor installed, and
immediately started to work by simply connecting it to water supply and power source. The SBS features at: highly integrity, movable, free of civil works, etc. It can be laid on roof top, outdoor, optional thermal store system. An ideal solution to thermal supply, the remake of old boiler system.
Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MW
Projects
Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MWPressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MW

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now