Type: | Submersible |
---|---|
Contact: | Contact |
Output Signal Type: | Analog Type |
Production Process: | Integration |
Feature: | SemiConductor |
Material: | Stainless Steel |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Application | Key features |
• Geothermal water measurement • Geothermal water intaking • Cooling water detection of thermal power plant • Thermal boiler • Hydrology detection • Power units • Hydropower |
• Pressure type: Gauge Pressure • Range: From0~1…500mH2O • Accuracy: ±0.25%F.S, ±0.5%F.S • Stability0.15%F.S/Year(typical), 0.25%F.S/Year(maximum) • Customized working temperature: -20ºC~120ºC • Signal Output:4~20mA, 0/1~5V, 0~10V • Power supply: 10/11~30V, 8~24V • Diffused silicon-oil fill system • Ingress Protection: IP68 • OEM: Available |
Electrical connection | |||
Cable | two wires | three wires | GX16-7 |
Red | power supply | power supply | 1 |
Blue/Green | output | output | 2 |
Black | shield | GND | 3 |
Yellow | - | Shield | 4 |
Signal output | |||
Two wires | 4-20 mA | ||
Three wires | 0/1~5V, 0~10V |
Application-based classification | |
Type A | the receiving instrument is close |
Type B | the receiving instrument is far away |
Type C | the installation occurs at the mouth of the well |
Measuring range | 0~1...500mH2O | Insulation | >100MΩ@50V | |
Overload pressure | 1.5 times of rated pressure | Electric strength | 500V@60second | |
Burst pressure | 3 times of rated pressure | Lightening protection | Withstand Voltage in Air: 8000V, Withstand Voltage of Housing and Cable: 4000V | |
Accuracy | ±0.25%F.S ;±0.5%F.S;(air line is for higher accuracy) | Response time | 10 mS | |
Stability | 0.15%F.S/Y, 0.25%F.S/Ymax | Safety level | intrinsically safe E; Explosion proof D | |
Work temp. | -20~100ºC(-20~120ºC Customize) | Vibration/shock | 10g/5~2000Hz, axes X/Y/Z20g sine 11ms | |
Compensatetemp | -10~70ºC,(Customizable for full temperature range) |
EMC | EN50081-1/-2; EN50082-2 | |
Medium compatibility | ||||
Electric parameters | Two wires | Three wires | ||
Output signal | 4~20mA | 0~5Vdc | 1~5Vdc | 0~10Vdc |
Power supply | 10~36Vdc | 6~24Vdc/ac | 11~30Vdc/ac | |
Load resistance | (U-10)/0.02(Ω) | >100k Ω | ||
Electric connection | Waterproof wire jacket + Rectangular seals + O-rings + Sealant + Glues pouring (Ingress Protection IP68) | |||
Pressure connection | immersed, split type |
Suppliers with verified business licenses