Electrode Boiler Phase Transition Electric Steam Boiler 2.8MW 85c 240m3/H

After-sales Service: Maintenance Free
Warranty: 10 Years
Type: Stainless Steel Heating Equipment
Certification: ISO, ASME
Structure: Vertical Type
Brand: Runpaq
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Zhejiang, China
Fast Delivery
The supplier can deliver the goods within 30 days
Customization from Samples
The supplier provides sample based customization services
Customization from Designs
The supplier provides design based customization services
ODM Services
The supplier provides ODM services
to see all verified strength labels (7)

Basic Info.

Model NO.
ZKD
Thermal Capacity
240 @10000 Kcal/H
Input Power
2880 Kw
AMP
4608 a
Thermal Water Flow
240 M3/H
Pressure Drop
40kpa
Connect
DN200
Shipping Weight
9 Tons
Main equipment Dimension
3000*2000*2700mm
Circuit Breaker
630A * 8 Pieces
Suggested Power Cable Spec
4*400mm2 X 8 Sets
Transformer Capacity
3200 kVA
Transport Package
Wooden Case
Specification
2.8MW
Trademark
Liyuan
Origin
China

Product Description

Electrode Boiler Phase Transition Electric Steam Boiler 2.8MW 85C 240m3/h

The vacuum electric boiler to generate hot water up to 85 ºC for various applications. Its thermal supply range: 0.1 - 2.8MW.

Operation principle
This vacuum electric boiler (hot water): thermal transfer is realized via a built-in heat exchanger, phase transition is done. Water has low boiling temperature under low pressure condition. The boiler use electricity flowing through the heating tube resistance to heat media water inside a closed vacuum chamber. The electricity is converted into thermal. The general process is: media water absorbs thermal to be converted into steam, that will rise to heat exchanger, then thermal is transferred to the water inside the heat exchanger tube during the condensation. so the cold thermal supply water temperature is increased by absorbing thermal. Finally, thermal is supplied to where is needed.

The vacuum electric boiler (hot water), use the principle of phase transition, the same media water will be heated forever. This doesn't like the traditional electric boiler's heating tubes, which are easily scaled, hence the shorter life span. The scale trouble will never happen on the vacuum electric vacuum boiler. The imported high performance electric heating units, ensures the boiler stably run in long term, life span over 20 years.
Electrode Boiler Phase Transition Electric Steam Boiler 2.8MW 85c 240m3/H
Key features
1. Safe and reliable
The boiler runs under vacuum condition, so it is not classfied to be pressure vessel. Triple protections ensure the safely run.
2. Extremely long service life
It is indirectly heated, the external thermal supply water doesn't contact with the heating tubes, so there'll be never scaling, life span over 20 years.
3. Multi functions
Multi thermal supply channels, meet various client's requirements.
4. Economic and environment friendly
No pollution, low noise, meet demanding environmental requirements.
Electrode Boiler Phase Transition Electric Steam Boiler 2.8MW 85c 240m3/HTechnical data
Model ZKD- 0.1 0.2 0.4 0.5 0.6 0.7 0.9 1.2 1.4 1.8 2.1 2.4 2.8
Rated thermal supply 104 kcal/h 10 20 30 40 50 60 80 100 120 150 180 200 240
Input power kW 120 240 360 480 600 720 960 1200 1440 1800 2100 2400 2880
Amp A 192 384 576 768 960 1152 1536 1920 2304 2700 3456 3600 4608
A style heat exchanger (Δt=10ºC, inlet/outlet temperature 45/55ºC or 50/60ºC)
Thermal supply water flow m3 /h 10 20 30 40 50 60 80 100 120 150 180 200 240
Pressure drop kPa 30 34 12 20 20 20 22 22 29 48 26 30 40
Connect port DN(mm) 40 50 65 80 80 100 100 125 125 150 200 200 20
B style heat exchanger (Δt=20ºC, inlet/outlet temperature 40/60ºC)
Thermal supply water flow m3/h 5 10 15 20 25 30 40 50 60 75 90 100 120
Pressure drop kPa 16 17 5 10 10 10 11 12 15 26 35 40 55
Connect port DN(mm) 40 50 50 65 65 65 80 80 100 100 125 125 125
C style heat exchanger (Δt=25ºC, inlet/outlet temperature 50/75ºC or 60/85ºC)
Thermal supply water flow m3/h 4 8 12 16 20 24 32 40 48 60 72 80 96
Pressure drop kPa 16 17 5 10 10 10 11 12 15 26 35 40 55
Connect port DN(mm) 40 50 50 65 65 65 80 80 100 100 125 125 125
Overall dimension L (mm) 1250 1600 1600 1600 1600 2200 2200 2200 2200 2200 2700 2800 3000
W (mm) 1100 1200 1300 1400 1440 1500 1200 1300 1400 1500 1800 2000 2000
H (mm) 1360 1420 1600 1800 1900 1900 1800 1850 1900 2000 2400 2600 2700
Control cabinet dimension L (mm) - - - - - - 1200 1200 1200 1200 1200 1200 1200
W (mm) - - - - - - 700 700 700 700 700 700 700
H (mm) - - - - - - 2000 2000 2000 2000 2000 2000 2000
Circuit braker Amp 250 500 630 500 630 630 500 630 630 630 630 630 630
Nos 1 1 1 2 2 2 4 4 4 5 6 7 8
Suggested power cable spec mm2 3x95
+
2x50
3x240
+
2x120
3x400
+
2x185
4x240
2 sets
4x300
2 sets
4x400
2 sets
4x240
4 sets
4x300
4 sets
4x400
4 sets
4x300
5 sets
4x400
6 sets
4x400
7 sets
4x400
8 sets
Suggested transformer capacity >=kVA 150 300 400 600 700 1000 1200 1500 1800 2000 2500 3000 3200
Shipping weight Ton 0.7 1.0 1.2 1.35 1.8 2.3 3.2 3.7 4.3 5.0 7.5 8.0 9.0
Operation weight Ton 0.75 1.1 1.3 1.5 2.0 2.5 3.4 3.9 4.5 5.3 7.8 8.4 9.4
Note:
1. Adjustable hot water flow range: 50-120%
2. Power supply: 3Phase/5wires. GB standard pure copper strands, diameter to be followed by the standard ZR-Y JV in the air (numbers of cable layout match with the group quantity), please choose the cables by the rated Amp. installation instruction (pipe bury, through pipe of bridge, use larger specification by comparison to national compensation factor), brand & model of cable, distance. The nullline and earth cable should be at least 50% of phase cable.
3. The circuit breakers in distribution box, must be one-to-one matched with the breakers in the boiler group.
4. ZKD-0.9 and above models, control cabinet is split with the main boiler, 1.2m away from control cabinet to boiler (standard distance). The cable connect should be done by professionals (need be paid if cable length longer than 1.2m), standard cable laying is in the trench (it need be paid in case of bridged cable connection).
5. The boiler dimension is for reference only, the actual height will be decided by the inlet/outlet temperature difference in heat exchangers.
6. Power cable and transformer capacity are for reference only. They should be provided by client.
7. The definition of boiler model selection
Electrode Boiler Phase Transition Electric Steam Boiler 2.8MW 85c 240m3/H
Projects
Electrode Boiler Phase Transition Electric Steam Boiler 2.8MW 85c 240m3/HElectrode Boiler Phase Transition Electric Steam Boiler 2.8MW 85c 240m3/H

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now